Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	63
Date	08/12/14
Start Time	11:36:16
Diameter Midpoint
 10.9	16673.8
 11.3	179921
 11.8	269101
 12.2	162599
 12.6	121278
 13.1	96328.8
 13.6	73738.8
 14.1	55153.6
 14.6	36574.3
 15.1	25530.5
 15.7	15693
 16.3	10025.4
 16.8	5771.9
 17.5	2895.85
 18.1	1605.1
 18.8	943.238
 19.5	353.322
 20.2	275.038
 20.9	151.95
 21.7	145.565
 22.5	126.211
 23.3	176.244
 24.1	149.978
 25.0	154.234
 25.9	132.919
 26.9	104.04
 27.9	141.248
 28.9	161.657
 30.0	177.754
 31.1	157.621
 32.2	162.527
 33.4	114.229
 34.6	91.1869
 35.9	133.852
 37.2	119.832
 38.5	126.907
 40.0	153.067
 41.4	105.81
 42.9	101.276
 44.5	49.9675
 46.1	14.6629
 47.8	0
 49.6	0
 51.4	0
 53.3	0
 55.2	0
 57.3	0
 59.4	0
 61.5	0
 63.8	130.029
 66.1	656.039
 68.5	1392.18
 71.0	2095.7
 73.7	2406.77
 76.4	2709.59
 79.1	2490.13
 82.0	2052.29
 85.1	1561.36
 88.2	1243.1
 91.4	941.88
 94.7	753.001
 98.2	534.502
101.8	438.474
105.5	328.251
109.4	249.488
113.4	206.378
117.6	155.687
121.9	112.332
126.3	100.929
131.0	73.2169
135.8	76.1216
140.7	64.1319
145.9	53.2571
151.2	52.0964
156.8	55.5191
162.5	37.7408
168.5	34.4216
174.7	18.6603
181.1	29.4296
187.7	25.6995
194.6	14.9753
201.7	22.8059
209.1	10.217
216.7	20.9894
224.7	12.4603
232.9	19.5981
241.4	6.24588
250.3	5.54122
259.5	5.17726
269.0	12.785
278.8	11.0911
289.0	8.73635
299.6	8.08288
310.6	12.4121
322.0	11.7147
333.8	5.43554
346.0	9.61888
358.7	2.58831
371.8	6.62752
385.4	4.49839
399.5	2.27622
414.2	2.31897
429.4	4.72694
445.1	2.39366
461.4	0
478.3	1.44481
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1593
High Voltage	9875.25
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	12.1985
Mean(nm)	13.9964
Geo. Mean(nm)	12.9831
Mode(nm)	11.7574
Geo. Std. Dev.	1.32531
Total Concentration(#/cm)	1.09872e+006
Comment	